# # # NISSAN S14 SR20DET MAP ADDRESS (E) # # Variable,Start-Address,X,Y,Map size,value,Map-name #UNIT NAME TYPE_UNIT,S14(SR20DET),*,*,* #HIGH/LOW octane Fuel map. HIGH_FUEL,&HE100,16,16,256,1,High octane Fuel map REG_FUEL,&HEE00,16,16,256,1,Low octane Fuel map #HIGH/LOW octane Ignition time map. HIGH_FIRE,&HED00,16,16,256,1,High octane Ignition time REG_FIRE,&HE800,16,16,256,1,Low octane Ignition time #K required number K_DATA,&HE00A,2,1,2,1,K required number #Void blast-off time IGN_TIME,&HE01B,1,1,1,1,Void blast-off time #Feedback control FB_SWITCH,&HE038,1,1,1,1,Feedback control #VQ map VQ_MAP,&HE700,16,1,128,1,VQ map #Fuel/Ignition time TP scale TP_SCALE_FUEL,&HE0F0,16,1,16,1,TP scale (Fuel) TP_SCALE_FIRE,&HE490,16,1,16,1,TP scale (Ignition time) #Fuel/Ignition time RPM scale RPM_SCALE_FUEL,&HE0E0,16,1,16,50,RPM scale (Fuel) RPM_SCALE_FIRE,&HE480,16,1,16,50,RPM scale (Ignition time) #TTP MAX/MIN TTP_MAX,&HE3A0,16,1,16,1,TTP MAX TTP_MIN,&HE390,16,1,16,1,TTP MIN #TP Limit AF_LIMIT,&HE2F0,16,1,16,1,TP Limit #Acceleration increase volume ADD_FUEL,&HE200,16,1,16,1,Acceleration increase volume #Rev.Limit REV1_LIMIT,&HE05C,2,1,2,12.5,Rev. Limit 1 REV2_LIMIT,&HE5C0,2,1,2,12.5,Rev. Limit 2 #Speed Limit SPEED1_LIMIT,&HE031,2,1,1,2,Speed Limit 1 SPEED2_LIMIT,&HE5C9,2,1,1,2,Speed Limit 2 SPEED3_LIMIT,&HE5CA,2,1,1,2,Speed Limit 3 #Add.map 1 ADD_MAP1,&HEA00,16,2,32,1,Temperature of the water value conversion #Add.map 2 ADD_MAP2,&HE220,16,1,16,1,I split and revise the crowded blast-off temperature of the water. #Add.map 3 ADD_MAP3,&HF000,16,16,256,1,Boost control duty value #Add.map 4 ADD_MAP4,&HF100,16,16,256,1,Boost control duty value